Search below for 'logbook_sop' for help on usage.
| November 2009 | ||||||
|---|---|---|---|---|---|---|
| Sun | Mon | Tue | Wed | Thu | Fri | Sat |
| 1 | 2 | 3 | 4 | 5 | 6 | 7 |
| 8 | 9 | 10 | 11 | 12 | 13 | 14 |
| 15 | 16 | 17 | 18 | 19 | 20 | 21 |
| 22 | 23 | 24 | 25 | 26 | 27 | 28 |
| 29 | 30 | |||||
Mark advised us to swap the two last quads again, but only on the patch panel side.
Because "Sodium" and "Ebi" are still dropping after swapping the patch cables, swapping the cable only on one side will tell us if the problem comes from the DOR card.
So we stopped run #114482, pDown'ed the DOMs on string 21, swapped previously swapped quads back to their original position, and started a new run #114483.
Here is the new order of the last DOMs on string 21:
62B 5053 Q15 R1B0622D05 COMM 21-57 Beryllium a2a379faa0ba UP4P0138 95 mA 95 mA 88V 62A 5054 Q15 R1B0622D05 COMM 21-58 Sodium ef3e4ba9cba4 TP4P0117 95 mA 95 mA 88V 63B 5055 Q15 R1B0622D05 COMM 21-59 Ebi 755fc7596d46 UP4P0108 92 mA 93 mA 88V 63A 5056 Q15 R1B0622D05 COMM 21-60 Bucatini fe6689460566 TP4P0103 92 mA 93 mA 88V 70B 5057 Q16 R1B0631D05 COMM 21-53 Sulfur 423ed83846c3 UP4P0214 64 mA 63 mA 88V 70A 5058 Q16 R1B0631D05 COMM 21-54 Fluorine 6f242f105485 TP4P0127 64 mA 63 mA 88V 71B 5059 Q16 R1B0631D05 COMM 21-55 Vanadium f85c7530c973 UP4P0158 64 mA 65 mA 88V 71A 5060 Q16 R1B0631D05 COMM 21-56 Oxygen 455c5f0f8a3f TP4P0121 64 mA 65 mA 88V
Erik Verhagen
|
08 Sep 2009 20:07 GMT
|
Ice Cube/DOMs
|
|