Oct 26, 2008

New work


By: Tex
Time: 20081026 1956Z
Music: Siousxie and the Banshees

OK, going for round 2. Also using 2 T series DOMs:
UP5P0818 Ecology
UP5P0912 North Dakota

Those will be there longer for some reason, so putting
those in first.

dthub2 is back in its original location. Powering it on.

OK, now I'm told that the U series have short penetrator cables
and so are not used for IceTop. Hmm, not sure why that is but
whatver - I asked MK to write a doc on the different DOMs
and cabling.

Anyway, now using:
TP5Y0219 Daewoo Nubira
TP6H7653 Balun

So 1/3 connectors will be these T series
2/4 will be the A series.

OK I misunderstood, still need to use U DOMs.
Back to:
UP5P0818 Ecology
UP5P0912 North Dakota

2040Z	OK to go. Turning on DOM PS.
	Using pUp. status shows:
dthub2 testdaq /mnt/data/testdaq/ status
-------------------------------------------------------------------------------
DTHUB2 SUMMARY:

DOR Port Qud DORserial# Stat Pos    NAME                       MBID      DOMID    RawC  CorrC  Volts    State
32B 5029 Q_9 R1B0489D04 COMM        North_Dakota           0216965aca20 UP5P0912  76 mA  77 mA  90V    iceboot
32A 5030 Q_9 R1B0489D04 COMM        Belly_Button           bbc6dac6c156 AP7P2027  76 mA  77 mA  90V    iceboot
33B 5031 Q_9 R1B0489D04 COMM        Ecology                467855cedc15 UP5P0818  79 mA  80 mA  89V    iceboot
33A 5032 Q_9 R1B0489D04 COMM        Spleen                 acaa767b7596 AP7P2014  79 mA  80 mA  89V    iceboot

2043Z	Doing the tests:
	current-test-configboot
DTHUB2 SUMMARY:

DOR Port Qud DORserial# Stat Pos    NAME                       MBID      DOMID    RawC  CorrC  Volts    State
32B 5029 Q_9 R1B0489D04 COMM                               000000000000           60 mA  61 mA  90V configboot
32A 5030 Q_9 R1B0489D04 COMM                               000000000000           60 mA  61 mA  90V configboot
33B 5031 Q_9 R1B0489D04 COMM                               000000000000           62 mA  63 mA  89V configboot
33A 5032 Q_9 R1B0489D04 COMM                               000000000000           62 mA  63 mA  89V configboot

	current-test-iceboot
DTHUB2 SUMMARY:

DOR Port Qud DORserial# Stat Pos    NAME                       MBID      DOMID    RawC  CorrC  Volts    State
32B 5029 Q_9 R1B0489D04 COMM        North_Dakota           0216965aca20 UP5P0912  76 mA  77 mA  90V    iceboot
32A 5030 Q_9 R1B0489D04 COMM        Belly_Button           bbc6dac6c156 AP7P2027  76 mA  77 mA  90V    iceboot
33B 5031 Q_9 R1B0489D04 COMM        Ecology                467855cedc15 UP5P0818  79 mA  80 mA  89V    iceboot
33A 5032 Q_9 R1B0489D04 COMM        Spleen                 acaa767b7596 AP7P2014  79 mA  80 mA  89V    iceboot

OK, looks good to me, doing pUp 3 so they can stay warm.
DTHUB2 SUMMARY:

DOR Port Qud DORserial# Stat Pos    NAME                       MBID      DOMID    RawC  CorrC  Volts    State
32B 5029 Q_9 R1B0489D04 COMM        North_Dakota           0216965aca20 UP5P0912  76 mA  77 mA  90V    iceboot
32A 5030 Q_9 R1B0489D04 COMM        Belly_Button           bbc6dac6c156 AP7P2027  76 mA  77 mA  90V    iceboot
33B 5031 Q_9 R1B0489D04 COMM        Ecology                467855cedc15 UP5P0818  79 mA  80 mA  89V    iceboot
33A 5032 Q_9 R1B0489D04 COMM        Spleen                 acaa767b7596 AP7P2014  79 mA  80 mA  89V    iceboot

Emailing MK.


Edgar Nielsen | 26 Oct 2008 15:45 GMT | Ice Cube/Testing | | permalink